IR to RS232 Codes Output Table for RCV-5000 Infrared Receiver

Feral - Key West QS440/1 Quad Video Switcher

Celadon Inc. 
RCV-5000  IR to RS-232 Output Table
Device: Feral - Key West QS440/1 Quad Video Switcher
Infrared Remote Control: Philips PRONTO, Niles Intellicontrol
Infrared Code Format: NEC - Device ID: 7B02
Infrared Pronto Data File(s): See "IR Code Read Me - RCV-5000.txt" for complete description
Infrared Receiver: Celadon RCV-5000 Infrared to RS-232 Receiver
RCV-5000 Data File: feral1_r.hex
Data: 9600 Baud, 8, N, 1, ASCII Output
Standard Transmit and Receive pinout
Command Pronto Button RCV-5000 Output
Set Background Black 0 aB+<cr>
Set Background White 1 aB-<cr>
Set Chroma Value - Increment 2 aC1+<cr>
Set Chroma Value - Decrement 3 aC1-<cr>
Set Chroma Value - Normalize 4 aC1@<cr>
Freeze Routine - Freeze ON - CH1 5 aE1+<cr>
Freeze Routine - Freeze ON - CH2 6 aE2+<cr>
Freeze Routine - Freeze ON - CH3 7 aE3+<cr>
Freeze Routine - Freeze ON - CH4 8 aE4+<cr>
Freeze Routine - Freeze OFF - CH1 9 aE1-<cr>
Freeze Routine - Freeze OFF - CH2 10 aE2-<cr>
Freeze Routine - Freeze OFF - CH3 11 aE3-<cr>
Freeze Routine - Freeze OFF - CH4 12 aE4-<cr>
Hue Value Routine - Increment 13 aH1+<cr>
Hue Value Routine - Decrement 14 aH1-<cr>
Hue Value Routine - Normalize 15 aH1@<cr>
Luminance Value Routine - Increment 16 aL1+<cr>
Luminance Value Routine - Decrement 17 aL1-<cr>
Luminance Value Routine - Normalize 18 aL1@<cr>
Priority Command - ZAP 1 19 aP@0<cr>
Priority Command - Channel 1 20 aP@1<cr>
Priority Command - Channel 2 21 aP@2<cr>
Priority Command - Channel 3 22 aP@3<cr>
Priority Command - Channel 4 23 aP@4<cr>
Priority Command - ZAP 2 24 aP@5<cr>
Recall from EEPROM Routine - Current Channel Setting 25 aR@C<cr>
Recall from EEPROM Routine - Settings for All Channels 26 aR@A<cr>
Recall from EEPROM Routine - Initial Settings 27 aR@I<cr>
Recall from EEPROM Routine - Normal Settings 28 aR@N<cr>
Recall from EEPROM Routine - Power On Reset Settings 29 aR@P<cr>
Store to EEPROM Routine - Current Channel Setting 30 aT@C<cr>
Store to EEPROM Routine - Settings for All Channels 31 aT@I<cr>
Store to EEPROM Routine - Initial Settings 32 aT@P<cr>
Store to EEPROM Routine - Normal Settings 33 aT@N<cr>
Store to EEPROM Routine - Power On Reset Settings 34 aT@A<cr>
Set Setup Value Routine - Increment 35 aS1+<cr>
Set Setup Value Routine - Decrement 36 aS1-<cr>
Set Setup Value Routine - Normalize 37 aS1@<cr>
Active Channel Select - Matrix OCF 38 av0<cr>
Active Channel Select - Scaler Channel 1 39 av1<cr>
Active Channel Select - Scaler Channel 2 40 av2<cr>
Active Channel Select - Scaler Channel 3 41 av3<cr>
Active Channel Select - Scaler Channel 4 42 av4<cr>
Select and Update crosspoint for MAX456 - input1/output1 43 ax11<cr>
Select and Update crosspoint for MAX456 - input1/output2 44 ax12<cr>
Select and Update crosspoint for MAX456 - input1/output3 45 ax13<cr>
Select and Update crosspoint for MAX456 - input1/output4 46 ax14<cr>
Select and Update crosspoint for MAX456 - input2/output1 47 ax21<cr>
Select and Update crosspoint for MAX456 - input2/output2 48 ax22<cr>
Select and Update crosspoint for MAX456 - input2/output3 49 ax23<cr>
Select and Update crosspoint for MAX456 - input2/output4 50 ax24<cr>
Select and Update crosspoint for MAX456 - input3/output1 51 ax31<cr>
Select and Update crosspoint for MAX456 - input3/output2 52 ax32<cr>
Select and Update crosspoint for MAX456 - input3/output3 53 ax33<cr>
Select and Update crosspoint for MAX456 - input3/output4 54 ax34<cr>
Select and Update crosspoint for MAX456 - input4/output1 55 ax41<cr>
Select and Update crosspoint for MAX456 - input4/output2 56 ax42<cr>
Select and Update crosspoint for MAX456 - input4/output3 57 ax43<cr>
Select and Update crosspoint for MAX456 - input4/output4 58 ax44<cr>
Select and Update crosspoint for MAX456 - Return Crosspoint Setting 59 ax@?
Select and Update crosspoint for MAX456 - Store xpoints to EEPROM 60 ax@s
Select and Update crosspoint for MAX456 - Recall xpoints from EEPROM 61 ax@r
Video Control Routine - Video ON 62 aV+<cr>
Video Control Routine - Video OFF 63 aV-<cr>
Video Control Routine - Video Status Inquiry 1 on, 0 off 64 aV?<cr>
Video Control Routine - Video Composite 65 aVC<cr>
Video Control Routine - Video Component 66 aVS<cr>
Make Channel Inactive 67 aV0<cr>
Make Channel Active 68 aV1<cr>
Celadon, Inc.
50 Mitchell Blvd.
San Rafael, CA 94903
Sales: (408) 292-1755
Main Tel: (415) 472-1177
Main Fax: (415) 472-1179
sales@celadon.com

Download the Infrared (IR) Code Files for the Pronto Remotes (.ccf and .pcf)

Please contact us to inquire about pricing and availability for our remote control products or call our sales and applications engineering staff at (408) 292-1755.

Celadon, Inc. | 50 Mitchell Blvd. | San Rafael, CA 94903 U.S.A. | Sales: +1 (408) 292-1755 | Fax: +1 (408) 292-1754
© Celadon, Inc. 2010 All Rights Reserved